Susitna Project. Fixed cone vales [sic] N2 supersaturation /

Harza-Ebasco performed an evaluation of the fixed cone valves that Acres American computed to be effective for the proposed Watana dam and Devil Canyon dam. The purpose of the valves is to mitigate nitrogen gas supersaturation in the Susitna River downstream of the dams.

Saved in:
Bibliographic Details
Alternate Title:Susitna Project. Fixed cone vales N₂ supersaturation

Susitna Project. Fixed cone valves N₂ supersaturation

Fixed cone vales N₂ supersaturation

Fixed cone valves N₂ supersaturation

Susitna Project. Fixed cone vaves nitrogen supersaturation

Susitna Project. Fixed cone valves nitrogen supersaturation

Fixed cone vaves nitrogen supersaturation

Fixed cone valves nitrogen supersaturation
Main Author: Coleman, H. W.,
Corporate Contributor(s):HARZA-EBASCO Susitna Joint Venture.
Report Numbers:APA 3058
Series:Document (Susitna Hydroelectric Project) ; no. 3058.
Subjects:
Online Access:Link to Full Text
Library Holdings:Print Versions
LEADER 02982ctm a2200601Ia 4500
001 2037661
003 SIRSI
005 20140515085920.0
007 ta
007 cr bn||||a||||
008 140514s1984 xx a bt 000 0 eng d
040 |a RLA  |c RLA  |d RLA 
035 |a (OCoLC)879653030 
043 |a n-us-ak 
050 4 |a TK1425.S8  |b A23 no. 3058 
088 |a APA 3058 
049 |a RLAA 
100 1 |a Coleman, H. W.,  |e author. 
245 1 0 |a Susitna Project.  |p Fixed cone vales [sic] N2 supersaturation /  |c from H.W. Coleman. 
246 3 |a Susitna Project.  |p Fixed cone vales N₂ supersaturation 
246 3 |a Susitna Project.  |p Fixed cone valves N₂ supersaturation 
246 3 |a Fixed cone vales N₂ supersaturation 
246 3 |a Fixed cone valves N₂ supersaturation 
246 3 |a Susitna Project.  |p Fixed cone vaves nitrogen supersaturation 
246 3 |a Susitna Project.  |p Fixed cone valves nitrogen supersaturation 
246 3 |a Fixed cone vaves nitrogen supersaturation 
246 3 |a Fixed cone valves nitrogen supersaturation 
260 |c 1984 Aug. 22. 
300 |a 4, 13, 11, [4] p. :  |b ill. ;  |c 28 cm. 
336 |a text  |b txt  |2 rdacontent 
337 |a unmediated  |b n  |2 rdamedia 
338 |a volume  |b nc  |2 rdacarrier 
490 1 |a Harza-Ebasco Susitna Joint Venture document ;  |v no. 3058 
500 |a Title from subject line. 
500 |a "Harza-Ebasco Susitna Joint Venture, memorandum." 
500 |a Memorandum to "EJG, JHT [i.e. J.H. Thrall], WEL, AZ, FGD" from H.W. Coleman of Harza-Ebasco Susitna Joint Venture, Chicago Office and dated August 22, 1984. 
500 |a "August 22, 1984." 
500 |a This memorandum is accompanied by handwritten calculations computed by "JEB" (13 pages) and by "HWC" [i.e. H.W. Coleman] (11 pages) and a brochure on Howell-Bunger valves (4 pages). 
500 |a Series statement from label on first page of memorandum. 
510 3 |a Assigned APA Document no. 3058 in the Susitna Hydroelectric Project document index. 
530 |a Available also in electronic format on the Internet. 
520 |a Harza-Ebasco performed an evaluation of the fixed cone valves that Acres American computed to be effective for the proposed Watana dam and Devil Canyon dam. The purpose of the valves is to mitigate nitrogen gas supersaturation in the Susitna River downstream of the dams. 
504 |a Includes bibliographical references (p. 1 of memorandum). 
650 0 |a Nitrogen supersaturation  |z Alaska  |z Susitna River. 
650 0 |a Electric power-plants  |x Piping  |x Valves. 
650 0 |a Hydroelectric power plants  |x Environmental aspects  |z Alaska  |z Susitna River. 
650 0 |a Dams  |x Environmental aspects  |z Alaska  |z Susitna River. 
655 0 |a Memorandums. 
710 2 |a HARZA-EBASCO Susitna Joint Venture. 
830 0 |a Document (Susitna Hydroelectric Project) ;  |v no. 3058. 
098 |a APA 03058 
856 4 1 |u https://www.arlis.org/docs/vol1/Susitna/30/APA3058.pdf  |z ARLIS Document Server 
596 |a 9 10